Manage and streamline operations across multiple locations, sales channels, and employees to has improve efficiency and your bottom line.

Single Phase Voltage Monitoring Relay RN-119

Rated 0 out of 5
(0 customer reviews)

Original price was: ৳  4,347.00.Current price is: ৳  2,500.00.

RN-119 is designed to disconnect the household and industrial single-phase load in case of unacceptable voltage fluctuations in the mains, and then automatically turn on after restoration of the mains parameters.

In stock

  • Estimated Delivery: 3-7 days from the date of order.
  • Free Shipping & Returns: On all orders over Tk. 10,000.00

Secure Payment System :

Description

Description

RN-119 is designed to disconnect the household and industrial single-phase load in case of unacceptable voltage fluctuations in the mains, and then automatically turn on after restoration of the mains parameters. In case of load power of up to 2.3 kW (current is up to 10A) for RN-118 or load power of up to 3.6 kW (current is up to 16A) for RN-119, the disconnection is done directly by the device the output contacts of which are included in power supply load outage. In case of higher power, the disconnection is done by the magnetic contactor of the appropriate power, the output contacts of the device are connected to the coil power supply for circuit disconnection (MC is not included in the delivery set).

RN-118/RN-119 detects the maximum and minimum voltage values from the moment the power supply voltage is applied to the device or since the last time the stored values were viewed.

RN-118/RN-119 protects single phase loads from Neutral break condition, when reverse voltage flows through neutral and 415V (linear voltage) apprears instead of 240V (phase voltage).

RN-118/RN-119 indicates the actual value (true RMS) of the input voltage and the state of the output relay contacts.

RN-118/RN-119 has inbuilt ON delay timer programmable from 5 sec to 900 sec.

The device can be operated in four independent modes:

  • Over and Under Voltage Relay;
  • Over Voltage Relay;
  • Under Voltage Relay;
  • ON Delay Relay.

Additional Information:

  • Item Code: RN-118 and RN-119
  • Port of Dispatch: New Delhi, India
Installation (mounting) of the device Standard 35 mm DIN-rail
Protection class rating of the front panel IP40
Protection class rating of the terminal block IP20
Electric shock protection class II
Climatic design version NC 3.1
Permissible contamination level II
Overvoltage category II
Rated voltage of insulation, V 450
Rated impulse withstand voltage, kV 2.5
Conductor cross-section for connecting to terminals, mm² 0.3 – 3.3
Tightening torque of the terminal screws of input contacts, N*m 0.4

Basic Technical Specifications

Description Value
AC single-phase operating supply voltage, V 230/240
Mains frequency, Hz 47 – 65
Harmonic composition (unsinusoidality) of supply voltage EN 50160
Control range for Umin, V 160 – 220
Control range for Umах, V 230 – 290
Control range  for AR (ton), s 5 – 900
Fixed time of Umах response, s 0.5
Fixed time of response in case of voltage spike of more than 420 V when pulse duration reaching more than 1.5 ms, max., s 0.02
Fixed off-delay due to Umin, s 7
Fixed time of response when voltage reducing less than 145 V, s 0.15
Maximum switched current (with active load) of RN-118, A 10
Maximum switched current (with active load) of RN-119, A 16
Accuracy of determination of the voltage operation threshold, V Up to 3
Minimum voltage when maintaining serviceability, V 100
Maximum switched current with active load, V 420
Hysteresis of overvoltage release, V 4 – 5
Power consumption (when load is not connected), max., W 2
Commutation life of output contacts:

  • under load of 16 A, min., time
  • under load of 5 A, min., time
 100 thousand

1 million

Overall dimensions (S-type module) – height * width * length, mm 90 x 65 x 18
Weight, max., kg 0.10
The device remains operational capability in any position in space
Housing material – self-extinguishing plastic

Output Contacts Specifications

Operation mode Max. current at U~250 V, A Max. switching power, kVA Max. continuous permissible AC / DC voltage, V Max. current at

Ucont=30 V, A

cos φ=1 10 (RN-118)

16 (RN-119)

2.3 (RN-118)

3.6 (RN-119)

250 5
cos φ=0.4 5 1.1

The device meets the requirements of the following:

  • EN 60947-1, Low-voltage switchgear and controlgear; Part 1; General rules;
  • EN 60947-6-2, Low-voltage switchgear and controlgear; Part 6-2; Multiple function equipment; Control and protective switching devices;
  • EN 55011, Electromagnetic compatibility; Industrial, scientific and medical RF equipment; Electromagnetic interference characteristics; Limits and methods of measurement;
  • IEC 61000-4-2, Electromagnetic compatibility; Part 4-2; Testing and measurement techniques; Electrostatic discharge immunity test.

Additional information

Weight 0.15 g
Dimensions 90 × 18 × 65 mm
Color

White

Reviews

There are no reviews yet.

Be the first to review “Single Phase Voltage Monitoring Relay RN-119”

Your email address will not be published. Required fields are marked *

Related Products